false
Catalog
CHEST 2024 Pulmonary and Critical Care Medicine (P ...
VAPS download pre adjustments
VAPS download pre adjustments
Back to course
Pdf Summary
The provided document details compliance and therapy reports for a patient using an AirCurve 10 ST-A device from 10/20/2023 to 11/07/2023. Here’s a summary of the key points:<br /><br />### Compliance Report<br />- **Usage Duration**: The device was used every day (19 out of 19 days) during the reporting period.<br /> - For 18 days, the usage was at least 4 hours.<br /> - On one day, the usage fell short of 4 hours.<br /><br />- **Total Usage**:<br /> - The total accumulated usage was 163 hours and 48 minutes.<br /> - Average daily usage was 8 hours and 37 minutes.<br /><br />- **Device Information**:<br /> - Device: AirCurve 10 ST-A<br /> - Mode: iVAPS<br /> - Target Alveolar Ventilation: 3.8 L/min<br /> - EPAP: 14 cmH2O<br /> - Minimum Pressure Support (PS): 4 cmH2O<br /> - Maximum PS: 6 cmH2O<br /> - Target Patient Rate: 15 breaths per minute (bpm)<br /><br />- **Leak Rates**: <br /> - Median leak: 21.0 L/min<br /> - 95th percentile: 51.6 L/min<br /> - Maximum: 65.3 L/min<br /><br />- **Event Rates**:<br /> - Apnea Index (AI): 0.0 events/hour<br /> - Hypopnea Index (HI): 0.5 events/hour<br /> - Apnea-Hypopnea Index (AHI): 0.5 events/hour<br /><br />### Therapy Report<br />- **Usage**:<br /> - 100% compliance (19 out of 19 days)<br /> - On average, used 8.6 hours per day<br /><br />- **Leak Threshold**: Set at 24.0 L/min <br /> - Median leak: 21.0 L/min<br /> - 95th percentile: 51.6 L/min<br /> - Maximum: 65.3 L/min<br /><br />- **Pressure Details**:<br /> - EPAP: Set at 14.0 cmH2O<br /> - PS Range: 4.0 to 6.0 cmH2O<br /><br />- **Volume and Rate**:<br /> - Median Tidal Volume: 203 ml <br /> - Respiratory Rate: median 24 bpm, max 38 bpm, 95th percentile 31 bpm<br /><br />- **Spontaneous Breaths**:<br /> - Triggered: 91%<br /> - Cycled: 23%<br /><br />- **Ventilation**:<br /> - Median Minute Ventilation: 5.2 L/min<br /> - Median Alveolar Ventilation: 3.2 L/min<br /><br />- **I:E Ratio**: <br /> - Median: 1:1.74<br /><br />This information indicates consistent device usage, effective management of prescribed therapy settings, and generally adequate control of leaks and respiratory events during the monitored period.
Keywords
AirCurve 10 ST-A
compliance report
therapy report
usage duration
leak rates
event rates
pressure details
ventilation
respiratory rate
spontaneous breaths
©
|
American College of Chest Physicians
®
×
Please select your language
1
English